Status Updates From Transducer Interfacing Hand...
Transducer Interfacing Handbook: A Guide to Analog Signal Conditioning by
Status Updates Showing 1-3 of 3
Nick
is on page 220 of 231
"Drive the transducer cable shield, S, with the common mode signal source […] to reduce the effective cable capacitance, as fig. 15-3 shows. [p. 218 ]" How does the guard reduce the effective cable capacitance? There’s C dv/dt. C remains the same. dv/dt also remains the same, because driving the shield with the common mode voltage [aka guarding] is a DC action.
— Jul 24, 2026 12:14PM
Add a comment
Nick
is on page 209 of 231
Discussion of hot wire anemometers on pp. 205-207 .
— Jul 23, 2026 11:21AM